Chimney Cap
The crowning detail on your roofline — a chimney cap that looks intentional.
Learn moreOlder and architecturally interesting chimneys often have offsets, bends, or odd cross-sections that a rigid liner simply can't pass — which is exactly the situation that leaves a handsome fireplace smoking or hard to light. A flexible stainless liner (316Ti for solid fuel, 304 for gas) snakes through those turns and gives the flue a smooth, correctly sized path, so the centerpiece draws cleanly and stays a pleasure to use. The liner is UL-1777 listed and carries a lifetime warranty. You keep the character of the original chimney and gain a fireplace that performs.
What this comes down to is a material choice, not a separate service: when a flue needs a liner, should it be the flexible corrugated stainless tube or a rigid one? Flexible wins precisely when the geometry defeats rigid pipe — a chimney with an offset or 'dogleg,' an elbow at the smoke chamber, an out-of-round or shouldered clay tile, or a throat too tight to feed a stiff length through. The corrugation lets the liner bend around the bends and compress through the pinch points while still sealing as one continuous channel. It sits underneath the broader relining decision, which may resolve to flexible, rigid, or cast-in-place; here we're specifically on the flexible option, chosen on geometry and appliance, whether the flue is being relined or lined for the first time.
Choosing flexible is a measurement before it's a purchase. We camera-scope the flue and map every offset, elbow, and dimensional pinch, then decide whether flexible is required — rigid won't pass — or merely preferred. If rigid would pass a straight, accessible flue, we'll say so, since rigid has smoother walls and marginally better draft and we don't sell flexible by default. Where the throat is tight, we run an oval-profile flexible liner of equal cross-sectional area so it passes where a round one won't. Alloy still tracks the fuel — 316Ti stainless for wood, oil, coal, or high-sulfur fuels, 304 where the fuel allows — because a flexible liner in the wrong alloy corrodes exactly as fast as any other.
Flexible is also the natural fit for appliance venting — much of why the type exists at all. Dropping a liner from a gas or wood fireplace insert down to the appliance collar nearly always means negotiating the offset between the flue and the insert's outlet, and flexible makes that positive, full-length connection where rigid would bind — never a non-connected 'slammer.' Venting a stove or a high-efficiency appliance through an existing masonry chimney poses the same geometry problem, and the flexible tube answers it. Because corrugation slightly slows draft and runs cooler, we add a liner-insulation wrap on solid-fuel and many appliance installs: it keeps flue temperature up for draft, holds creosote down, and maintains clearance to combustibles where the run passes near framing.
Installation is geometry-aware top to bottom: we feed the liner from above, ease it through each offset instead of forcing it, insulate or pour-mix as required, and lock positive top-plate and appliance-collar connectors so the corrugated run is gas-tight end to end. Then we prove it — a smoke or draft check confirms the sealed path, and we document the UL-1777 listing for your records and any warranty, which on flexible liners is usually conditional on annual sweeping. Where flue installation often builds a brand-new, straight flue best served by smooth clay or rigid, flexible is the retrofit answer for an existing crooked flue rigid can't follow. The same scoping, alloy-matching, and insulation discipline governs every flexible-liner install in every Dallas-area home we work in.
At Space Fireplace Services, a flexible chimney liner installation is never guesswork. We scope every job from a graded, photographed inspection first — the NFPA 211 level the evidence calls for — so the work is matched to what your flue and masonry actually need, with the report to prove it. The documented inspection is the record the flexible chimney liner installation is built on.
Chimney inspectionA flexible chimney liner installation isn't a matter of opinion — it's held to published national standards. Space Fireplace builds every job to the named codes below and documents it, so the work is provably right for an inspector, an insurer, or a future buyer. These are the universal standards; your city's permit and inspection requirements are confirmed with the local authority before we pull the job.
A flexible stainless liner from our team arrives as a UL-1777 listed lining system, certified for the application and documented for inspection, and we install it exactly to the manufacturer's instructions because the listing only holds that way.
Fuel dictates the alloy: 316Ti stainless where wood, oil, coal, or high-sulfur fuels burn, 304 where the fuel permits it. Put the flexible material in front of the wrong fuel and it corrodes early and voids the warranty.
Through the flue's offsets and elbows, the flexible liner is guided inside the manufacturer's listed bend radius rather than forced, so the corrugated wall arrives without a kink or tear in passages a rigid liner simply could not negotiate.
For solid-fuel work and many appliance installs, the flexible liner gets an insulation wrap that holds flue temperature for reliable draft and preserves clearance to combustibles where the run passes near framing: 2 in interior masonry and 1 in exterior per the IRC.
Codes cited are the established national standards (NFPA, UL, IRC) that govern this service. The adopted code edition, permit, and inspection requirements vary by city —Space Fireplace verifies them with your local authority having jurisdiction on every job.
We camera-map each offset, elbow, and pinch in the run so we know whether the flue truly needs a flexible liner or whether rigid would serve it just as well.
Diameter gets matched to the appliance and fuel, round or oval, alloy chosen to suit, and we settle the insulation question before anything goes in.
The liner feeds down from above, threading the bends, then we insulate it and lock positive connections at both the top plate and the collar.
A draft and smoke check closes it out, with UL-1777 documentation kept for your records and your warranty.
We've worked on 1,000+ DFW homes over 10+ years. Every job — small sweep or full rebuild — runs the same way: certified technicians, written quotes, photo reports, warranty in writing.
It snakes past offsets, elbows, and out-of-round tile that a rigid liner simply can't pass through.
The right liner type for gas and wood inserts and for high-efficiency appliance venting.
UL-1777 listed flexible stainless — transferable lifetime warranty
Insulated and oval-profile options for the tight, crooked, or solid-fuel flues that leave no room to spare.
Family-owned, CSIA-certified, NFPA 211–compliant. We're the team you call when you want it done right the first time — no rotating subcontractors, no upsell pressure, no surprises. Same techs, same trucks, same standard.

Plan on a Level 1 inspection every year — that's the NFPA cadence — with an actual sweep once buildup reaches 1/8" of creosote. For a fireplace you light through the season, that usually lands at once a heating season. Think of it as the upkeep that keeps the centerpiece of the room clean, drawing well, and ready to look its best.
Yes. The inspectors who assess your chimney hold current CSIA (Chimney Safety Institute of America) certifications — you can confirm them in the CSIA member directory at csia.org — and our fireplace installations are handled by NFI specialists. The craft that makes a hearth a showpiece starts with the people standing in front of it.
Yes — emergency response is available 24/7 (subject to crew availability) for active water leaks, an animal trapped in the flue, post-fire damage, and storm damage, same-day in most cases. A fireplace is the heart of a room; when it's at risk, we treat it that way.
Always. You get a written quote before a single tool comes out, with photos of exactly what we found. Final pricing tracks the chimney's real condition and anything additional the inspection surfaces — no surprises, just a clear picture of what your fireplace needs.
Yes — our annual maintenance membership runs $19.99/month ($240/year) and covers a yearly Level 1 inspection and sweep ($248 value), priority scheduling, 10% off all repairs, and emergency-response priority. Cancel anytime, no contract. It's the quiet way to keep your hearth looking and working its best year after year.
Last reviewed:
Other services in the Installation category.
Free written quote. Same-week scheduling. 24/7 emergency response when you need it.
Active leak, animal in flue, post-fire damage, or smoke event? Real humans on the line 7 AM to 12 AM every day — replies in under 2 minutes. Tech dispatch within 2 hours during business hours, subject to crew availability after-hours.
Emergency line