Chimney Inspection
A clear-eyed look at the centerpiece — what's beautiful, what needs attention.
Learn moreA pellet stove that's checked yearly keeps burning a clean, bright fire and stays the tidy focal point it was meant to be — instead of a sooty, sluggish unit. Our NFPA 211 annual inspection covers venting integrity, gaskets, exhaust paths, and electrical, with a full cleaning so the glass stays clear and the burn stays efficient. Many homeowner-insurance policies require it on the books. You get peace of mind, a stove that looks and runs its best, and the documentation to back it up.
A pellet stove is far more mechanical than a traditional fireplace — motors, fans, gaskets, an auger, and electronic controls all working together — which means more parts that wear and more places fly-ash collects. An annual inspection keeps all of it running safely and efficiently, and it's the surest way to dodge the mid-winter breakdown that always seems to land on the coldest night. We inspect pellet appliances thoroughly and pair the inspection with a full cleaning, so you enter the heating season on a verified, ready system.
The inspection takes in the whole appliance. We check the venting for blockage and a sound seal, examine the door and hopper gaskets that keep combustion air on its intended path, test the combustion and convection fans for wear and proper airflow, inspect the burn pot and ignition, and verify the electrical connections and safety switches. Each of those has to work in concert — a tired fan or a leaking gasket quietly erodes efficiency and heat output long before it fails outright.
Cleaning is part of the visit, never an add-on, because pellet exhaust drives fine fly-ash into places a casual wipe-down never reaches. We clean the burn pot, the ash traps, the heat-exchanger path, and the vent, clearing the buildup that fouls the flame, chokes airflow, and forces the stove to work harder than it should. A clean burn path is what gives back the efficiency and steady heat the stove had when it was new.
You're left with a written report of what we found and what to watch, plus straightforward maintenance recommendations. Booking the inspection before peak season means the small issues — a worn gasket, a tired fan, early buildup — get caught while they're cheap and easy to address, instead of surfacing during a cold-weather failure. It's the same pre-season diligence and honest reporting our technicians bring to every appliance, from our Dallas base to every job we take.
A pellet stove inspection isn't a matter of opinion — it's held to published national standards. Space Fireplace builds every job to the named codes below and documents it, so the work is provably right for an inspector, an insurer, or a future buyer. These are the universal standards; your city's permit and inspection requirements are confirmed with the local authority before we pull the job.
Our inspection confirms the listed PL-vent run on your pellet appliance is clear and its gasketed joints are sound, since a vent that leaks or clogs with fly ash is the most common pellet-stove safety fault.
Clearances to combustibles get re-measured against the stove's listing, because rooms change over time: furniture creeps closer, shelving goes up, a remodel reshapes the wall, and the required gap can quietly disappear after install.
While the stove runs, an ambient CO check verifies it burns and vents safely, and only then is it signed off for the season.
Codes cited are the established national standards (NFPA, UL, IRC) that govern this service. The adopted code edition, permit, and inspection requirements vary by city —Space Fireplace verifies them with your local authority having jurisdiction on every job.
Check venting, gaskets, fans, burn pot, wiring.
Full clean of burn pot, traps, and vent.
Verify ignition, airflow, and safe operation.
Written findings + maintenance recommendations.
We've worked on 1,000+ DFW homes over 10+ years. Every job — small sweep or full rebuild — runs the same way: certified technicians, written quotes, photo reports, warranty in writing.
Full venting + component safety check
Deep cleaning included
Catches issues before peak season
Written report with recommendations
Family-owned, CSIA-certified, NFPA 211–compliant. We're the team you call when you want it done right the first time — no rotating subcontractors, no upsell pressure, no surprises. Same techs, same trucks, same standard.

Plan on a Level 1 inspection every year — that's the NFPA cadence — with an actual sweep once buildup reaches 1/8" of creosote. For a fireplace you light through the season, that usually lands at once a heating season. Think of it as the upkeep that keeps the centerpiece of the room clean, drawing well, and ready to look its best.
Yes. The inspectors who assess your chimney hold current CSIA (Chimney Safety Institute of America) certifications — you can confirm them in the CSIA member directory at csia.org — and our fireplace installations are handled by NFI specialists. The craft that makes a hearth a showpiece starts with the people standing in front of it.
Yes — emergency response is available 24/7 (subject to crew availability) for active water leaks, an animal trapped in the flue, post-fire damage, and storm damage, same-day in most cases. A fireplace is the heart of a room; when it's at risk, we treat it that way.
Always. You get a written quote before a single tool comes out, with photos of exactly what we found. Final pricing tracks the chimney's real condition and anything additional the inspection surfaces — no surprises, just a clear picture of what your fireplace needs.
Yes — our annual maintenance membership runs $19.99/month ($240/year) and covers a yearly Level 1 inspection and sweep ($248 value), priority scheduling, 10% off all repairs, and emergency-response priority. Cancel anytime, no contract. It's the quiet way to keep your hearth looking and working its best year after year.
Last reviewed:
Other services in the Inspection category.
Free written quote. Same-week scheduling. 24/7 emergency response when you need it.
Active leak, animal in flue, post-fire damage, or smoke event? Real humans on the line 7 AM to 12 AM every day — replies in under 2 minutes. Tech dispatch within 2 hours during business hours, subject to crew availability after-hours.
Emergency line